{"id":8299,"date":"2025-01-29T11:14:00","date_gmt":"2025-01-29T10:14:00","guid":{"rendered":"https:\/\/www.luterbach-ag.ch\/produkte\/%productgroup%\/dust-extraction-systems\/"},"modified":"2025-04-01T09:56:23","modified_gmt":"2025-04-01T07:56:23","slug":"dust-extraction-systems","status":"publish","type":"products","link":"https:\/\/www.luterbach-ag.ch\/en\/products\/ventilation-technology\/dust-extraction-systems\/","title":{"rendered":"Dust extraction systems"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"8299\" class=\"elementor elementor-8299 elementor-2391\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-acebb94 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"acebb94\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-689481b\" data-id=\"689481b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ce86441 elementor-widget elementor-widget-text-editor\" data-id=\"ce86441\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Application examples:<\/h3><p>&nbsp;<\/p>\r\n<h4>Metal processing<\/h4>\r\n<p>In a large hall, components are welded and ground. The hall was completely blackened by metal dust that had accumulated over decades, even though decentralized extraction systems were in place. A path for material flow runs through the center.<\/p>\r\n<p><b>Solution:<\/b><br>The hall was cleaned, and an intermediate ceiling was installed below the truss. Since then, the air has been extracted at the facades, cleaned with a cartridge filter system, and combined with a <a href=\"https:\/\/www.luterbach-ag.ch\/en\/produkte\/ventilation-technology\/supply-and-exhaust-air-systems\/\" target=\"_blank\" rel=\"noopener\">supply and exhaust air system<\/a> that provides fresh air.<\/p><p>&nbsp;<\/p>\r\n<h4>Wooden windows<\/h4>\r\n<p>The wooden frames and windows are lightly sanded after flooding to break the raised fibers. Typically, the windows were sanded lying on trestles. The dust was not centrally extracted but spread throughout the production area.<\/p>\r\n<p><b>Solution 1:<\/b><br>The entire suspension remains in front of an extraction wall. The wall can be moved towards the component. The work is performed ergonomically on the vertical frame. The dust is removed and returned to the room through a HEPA filter.<\/p>\r\n<p><b>Solution 2:<\/b><br>The same principle as Solution 1, but the suspension is continuously moved.<\/p><p>&nbsp;<\/p>\r\n<h4>Welding shop<\/h4>\r\n<p>In the past, extraction systems with extraction arms were often used. Nowadays, it is evident that these are not efficiently used enough and, therefore, do not sufficiently protect employees from toxic dust.<\/p>\r\n<p><b>Solution:<\/b><br>Integral ventilation concept with source supply air at the workplaces and central extraction with cartridge filters.<\/p><p>&nbsp;<\/p>\r\n<h4>Orthopedic technology<\/h4>\r\n<p>In orthopedic technology, a lot of work is done with plaster models and plastics. A lot of dust is generated while working, and solvents are also used.<br>\r\nThe new building is planned as a Minergie Plus house, allowing only minimal air volumes.<\/p>\r\n<p><b>Solution:<\/b><br>&#8211; Recirculating filter system for dust and plastic particles<br>&#8211; Ventilated workstations for handling solvents, including ventilation and activated carbon filters<br>&#8211; Cabinets with integrated extraction and EI90<br>&#8211; Small paint booth for small painting jobs\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-9944f27\" data-id=\"9944f27\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3a0f12d elementor-widget elementor-widget-heading\" data-id=\"3a0f12d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Technical data:<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ffebb5 elementor-widget elementor-widget-text-editor\" data-id=\"0ffebb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><b>Basic components:<\/b><br \/>&#8211; Fans<br \/>&#8211; Filter systems<br \/>&#8211; Heating<br \/>&#8211; Heat recovery<\/p>\n<p><b>Materials:<\/b><br \/>&#8211; Galvanized steel<br \/>&#8211; Painted steel<br \/>&#8211; Stainless steel 1.4307 and 1.4404<\/p>\n<p><b>Air volumes:<\/b> 2,000 \u2013 80,000 m\u00b3\/h<\/p>\n<p><b>Temperatures:<\/b> Typically room temperature<\/p>\n<p><b>Filter systems:<\/b><br \/>&#8211; Fine filter ISO ePM1 70%<br \/>&#8211; HEPA filter up to H14<br \/>&#8211; Activated carbon<\/p>\n<p><b>Heating:<\/b><br \/>&#8211; Electric<br \/>&#8211; Hot Water<br \/>&#8211; Direct\/Indirect Gas<br \/>&#8211; Indirect oil<br \/>&#8211; Thermal oil<\/p>\n<p><b>Heat recovery:<\/b><br \/>&#8211; Static plate heat exchangers (up to 65% efficiency)<br \/>&#8211; Rotary heat exchangers (up to 85% efficiency)<br \/>&#8211; Sorption regenerators (up to 85% efficiency, including latent energy\/moisture)<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"featured_media":3591,"template":"","productgroup":[130],"class_list":["post-8299","products","type-products","status-publish","has-post-thumbnail","hentry","productgroup-ventilation-technology"],"_links":{"self":[{"href":"https:\/\/www.luterbach-ag.ch\/en\/wp-json\/wp\/v2\/products\/8299","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luterbach-ag.ch\/en\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.luterbach-ag.ch\/en\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":16,"href":"https:\/\/www.luterbach-ag.ch\/en\/wp-json\/wp\/v2\/products\/8299\/revisions"}],"predecessor-version":[{"id":9033,"href":"https:\/\/www.luterbach-ag.ch\/en\/wp-json\/wp\/v2\/products\/8299\/revisions\/9033"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luterbach-ag.ch\/en\/wp-json\/wp\/v2\/media\/3591"}],"wp:attachment":[{"href":"https:\/\/www.luterbach-ag.ch\/en\/wp-json\/wp\/v2\/media?parent=8299"}],"wp:term":[{"taxonomy":"productgroup","embeddable":true,"href":"https:\/\/www.luterbach-ag.ch\/en\/wp-json\/wp\/v2\/productgroup?post=8299"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}